Technical characteristics
  • BrandAgilent Technologies
  • Country of manufactureUnited States
Description

Analyzer of a range of the PSA Agilent Technologies E4445A series

Purpose of the analyzer of a range of Agilent E4445A of the PSA series:

The analyzer of a range Agilent E4445A of the PSA series is capable to carry out difficult single-button measurements, has a wide set of functionality and meets the most modern requirements for universality of application, speed, accuracy and dynamic range. Carrying out a wide range of measurements - from measurements in the field of millimetric waves and phase noise before search of collateral components and the analysis of modulation - the analyzer of a range Agilent E4445A of the PSA series provides realization of unique and comprehensive technical solutions when performing research and development and in the sphere of production of the equipment of the cellular and other again appearing systems of a radio communication, the equipment of space and defensive equipment.

Features of the analyzer of a range of Agilent E4445A of the PSA series:

  • Accuracy of measurements, highest in branch
  • Completely digital path of PCh
  • High-precision internal basic signal
  • Automatic internal fine tuning
  • Universal set of functionality
  • Unsurpassed combination of flexibility, speed of measurements, accuracy and dynamic range

Technical characteristics of the analyzer of a range of Agilent E4445A of the PSA series:

Parameters Values
Frequency parameters
Open entrance From 3 Hz to 13,2 GHz
The closed entrance From 10 MHz to 13,2 GHz
Strip Operating mode on harmonicas (number of a harmonica of N)
0 1- From 3 Hz to 3 GHz
1 1- From 2,85 GHz to 6,7 GHz
2 2- From 6,2 GHz to 13,2 GHz
3 4- From 12,8 GHz to 19,2 GHz
4 4- From 18,7 GHz to 26,5 GHz
5 4+ From 26,4 GHz to 31,15 GHz
Basic frequency Error ± [(time from the last fine tuning x aging speed) + temperature instability + pogreshnostkalibrovka]
Aging speed ± 1 x 10 −7 in a year
Temperaturnayanestabilnost
in the range from 20 to 30 °C

± 1 x 10 −8

Temperaturnayanestabilnost
in the range from 0 to 55 °C
± 5 x 10 −8
Calibration error ± 7 x 10 −8

Marker frequency counter
Error ± (frequency of a marker x error
basic frequency + 0,100 Hz)
Resolution of the counter 0,001 Hz
Counter error
differences of frequencies
± (difference of frequencies x error
basic frequency + 0,141 Hz)
Review strip (BPF mode and svipirovaniye) 0 Hz (a zero strip of the review), from 10 Hz to maximum
range frequencies for this model
Permission 2 Hz
Error ± [0,2% x strip of the review + review strip / (number of points of development − 1)]
Bandwidth
Range (a strip at the level minus 3,01 dB) From 1 Hz to 3 MHz (a step of 10%), 4, 5, 6 and 8 MHz
Error Bandwidth from 1 Hz to 1,5 MHz ± 2% nominally

Bandwidth
from 1,6 MHz to 3 MHz

center. CF frequency ≤ 3 GHz ± 7% nominally
center. CF frequency> 3 GHz ± 8% nominally
Bandwidth
from 4 to 8 MHz
center. CF frequency ≤ 3 GHz

± 15% nominally

center. CF frequency> 3 GHz ± 20% nominally
Squareness coefficient (selectivity) (on levels 4,1:1 nominally
Amplitude parameters

Measurement of amplitude

Measurement limits
signal level
From the average level of own
noise to max. safe
level of an entrance signal
Range of easing
entrance attenuator
From 0 to 70 dB, step 2 dB

Max. safe level of an entrance signal


Max. full capacity
+30 dBm (1 W)
With a preamplifier
(1DS complete set option)
+25 dBm
Indicator range
Logarithmic scale From 0,1 to 1 dB / put, a step 0,1 dB
From 1 to 20 dB / put, a step of 1 dB
(10 divisions of a large-scale grid)
Linear scale 10 divisions
Scale units dBm, dBmV, dbmkv, In and W
Absolute error of measurement of amplitude At a frequency of 50 MHz ±0,27 dB (±0,11 dB, type. mean.)
At all frequencies ± (0,27 + unevenness of ChH)
± (0,11 + unevenness of ChH), standard value
From 3 Hz to 3 GHz
(with 95%9noy reliability)

±0,24 dB
With a preamplifier (option 1DS) ± (0,45 + unevenness of ChH)
± (0,15 + unevenness of ChH), standard value

Coefficient of a standing wave of a vkhodnogonapryazheniye (KSVN) (Weakening of an attenuator ≥ 8 dB)



From 50 MHz to 3 GHz <1,13 nominally
From 3 to 18 GHz <1,27 nominally
From 18 to 26,5 GHz E <1,37 nominally
From 26,5 to 50 GHz <1,57 nominally
With a preamplifier (from 50 MHz to 3 GHz, oslabl. attenuator E4 <1,13 nominally
Basic level Range Logarithmic scale From-170 to +30 dBm, step 0,01 dB
Linear scale
From 707 pv to 7,07 B, a step of 1%

Permission
Logarithmic scale 0,01 dB
Linear scale ≤0,1% of basic level
Error 0 dB

General characteristics of the analyzer of a range of Agilent E4445A of the PSA series:

Food From 100 to 132 V, from 47 to 66 Hz and from 360 to 440 Hz
From 195 to 250 V, from 47 to 66 Hz

Power consumption
Operating mode
(food is included)
<260 W main mode
<450 W mode of full loading
Readiness mode <20 W
Range of temperatures Worker From 0 to +55 °C
Limit (storage) From-40 to +75 °C
Compatibility on electromagnetic hindrances Level of hindrances on power-supply circuits and the radiated hindrances
the publication 11/1990 Group 1 Class A meets standards of CISPR,
Overall dimensions (VKHSHKHG) 177 mm (7,0 inches) of X 426 mm (16,8 inches) of X 483 mm (19 inches)

Weight (without complete set options)
unpacked 23 kg (50 pounds), nominally
in packing 33 kg (73 pounds), nominally
Warranty period Three years

Information for the order:

E4445A the PSA series Agilent Technologies range Analyzer from 3 Hz to 13,2 GHz
E444kha-110 Vstr. a preamplifier in all strip of frequencies
E444kha-1DS Vstr. a preamplifier from 100 kHz to 3 GHz
E444kha-B7J Appar. means of digital demodulation
E4440A-122 Digitizer to 80 MHz
E4440A-140 Digitizer to 40 MHz
E444kha-123 Broadband exit of PCh of the switch of the preselector
E444kha-124 Exit of the video amplifier of axis Y
E444kha-H70 PCh exit 70 MHz
E444kha-111 USB interface
Shipping method
Contact the seller
Analyzer of a range of the PSA Agilent Technologies E4445A series
Analyzer of a range of the PSA Agilent Technologies E4445A series
for
by the goods
Your message must contain at least 20 symbols. The message must not be more than 2000 symbols.
Obligatory field is not filled
The field is wrongly filled
The field is wrongly filled
Compare0
ClearSelected items: 0