Currency RUB
Cabinets for automatic switching on of backup power ABP, BP, SCHAP buy in Rasskazovo
Buy Cabinets for automatic switching on of backup power ABP, BP, SCHAP
Cabinets for automatic switching on of backup power ABP, BP, SCHAP

Cabinets for automatic switching on of backup power ABP, BP, SCHAP

Products from producer
In stock
Reconfirm the price with seller
For example: +7(50)123-45-67
Payment:
Shipping:
Russia, Rasskazovo
(View map)
+7(4 
Display phones
10
10 years on Allbiz
Technical characteristics
  • Brand«СЕРВЕР»
  • Country of manufactureRussia
  • TypeEmergency input of the reserve
  • Mounting methodSuspended
  • Case materialMetal
  • ColorGrey
Description

Products: Built - in automatic inclusion of ATS backup, BP SCHAP buy in bulk for export from the manufacturer in Russia, Rasskazovo

Description: ABP is a device for a reliable system for monitoring the voltage in the main and backup power circuits, as well as for the disappearance, skew, phase sequence. ATS provides power supply voltage of 380V from one of two or more inputs (main, backup, DGU). ATS automatically switches the power to the backup input when the mains fails. ATS produces power distribution and protection of cable lines and equipment from overloads and short circuit currents. ATS allows you to visually control the operation of the inputs and possible violations of the voltage phases.

ATS possible device options:

  • ATS with priority of the first input:

Power supply to consumers is carried out exclusively from the first input. In the event of * * voltage failure on it, the ATS automatically switches to the second input. When voltage is restored on the first input, it automatically returns to this input.

  • ATS with equivalent inputs:

It can work for a long time, both from the first and from the second input. In the event of * * power failure at the first input or forced disconnection of the power supply, the ATS automatically switches to the second input, without returning to the first, regardless of the fact that the power can be restored on the first input. Automatic switching to the first input occurs in the event of * * * power failure on the second input. You can manually switch from one input to another.

  • ATS with independent inputs:

It can work in the mode when each input of the ATS works independently of the other for its consumer. In the event of failure of one of the inputs, all consumers are connected to a healthy input.

* * Under power failure in the ATS should be understood the absence of at least one phase, a violation of the phase rotation, the presence of phase voltage asymmetry.

With ABP devices can be combined:

- light indication and sound alarm;

- metering and distribution of electricity;

- devices for monitoring the load and power parameters.

Design ABP, SCHAP:

ABP panels are produced in two types: floor or mounted. The choice of model depends mainly on the rated current.

Completeness of delivery ABP, SCHAP:

  • The device ABP, SCHAP in accordance with the order
  • Door keys
  • Passport for the finished product
  • Electric scheme
  • Certificates for components (optional)

Production facilities: Russia, Rasskazovo

Packing: crates

Form of payment: prepayment

Delivery form: EXW (Tambov Region, Rasskazovo ) 

Producer: LLC SERVER

The company is a manufacturing enterprise and supplies its products to electric power, defense, metallurgy, machine - building, automotive and other systemically important industries throughout Russia and the CIS countries.

We make:

  • Rectifier unit B - TPE, B - TPV, V - TPP, TV, TE, TP, TVR, TER, TPR
  • Shredder Industrial Shredder
  • Medical waste shredder industrial shredder, plastic crushing
  • Thyristor rectifiers TE, TER, TP, TPR, TV, TVR, V - TPE, V - TPP, V - TPV
  • Air - water cooler VVO - 4
  • Shredder Waste Crusher
  • Digital control rectifier
  • Input - switchgear ASU
  • Switchboard of unilateral service of the ShchO70 series (ShchO70 - 1, ShchO70 - 2, ShchO70 - 3, ShchO91)
  • Switchboard floor type UERMS - R
  • Distribution point PR11 for residential buildings and public buildings
  • Distribution point PR - 22 and PR - 24 for residential buildings and public buildings
  • Distribution point PR80 for residential buildings and public buildings
  • Distribution cabinet ШРС and ШР11
  • Cabinets for the control of water, foam and gas fire extinguishing systems of series Ш 5900, 5100, 9500, 9700, Я5900, 9000, 9700
  • Powder - coated drying chamber control cabinet
  • Cabinets for automatic switching on of backup power ABP, BP, SCHAP
  • Engine control box Я5000
Shipping method
Payment method
Contact the seller
Cabinets for automatic switching on of backup power ABP, BP, SCHAP
Cabinets for automatic switching on of backup power ABP, BP, SCHAP
for
by the goods
Your message must contain at least 20 symbols. The message must not be more than 2000 symbols.
Obligatory field is not filled
The field is wrongly filled
The field is wrongly filled
Compare0
ClearSelected items: 0