- BrandАВ-50/70
- Country of manufactureRussia
The device high-voltage test AB-50/70 is developed for test of isolation of power cables and solid dielectrics by the straightened voltage, and also for test of solid dielectrics sinusoidal voltage with a frequency of 50 Hz.
- The device is calculated for operation under a canopy or in rooms at working values of air temperature from minus 10 °C to plus 40 °C, relative humidity of 80% at a temperature plus 20 °C and the atmospheric pressure of 84,0 - 106,7 kPa (630 – 800 mm Hg).
For test of cables with isolation from the sewed polyethylene at a frequency of 0,1 Hz the AB-45-0,1 SNCh-prefix is applicable to the Device AB-50/70. In more detail here...
TECHNICAL CHARACTERISTICS:
2.1. Tension of a power line of single-phase
alternating current, In, - 220±11
2.2. Device parameters at the straightened tension in the long mode (till 5 minutes) at nominal rate of tension in a network:
- the largest working tension, kV, - 70;
- the maximum working current, ma, - 30
2.3. Device parameters on an alternating voltage in the long mode (till 5 minutes) at nominal rate of tension in a network:
- the largest working tension (the operating value), kV, - 50;
- the greatest working current (the operating value), ma, - 40
2.4. Power consumption, kVA, no more - 2
2.5. The given error of measurement of output tension and current, %, no more - 3
2.6. Weight, kg, no more:
the control unit - 15
the block of a high voltage - 35
2.7. Overall dimensions:
the control unit - 320х200х355
the block of a high voltage - 270х295х660
2.8. Average service life - 10 years
COMPLETENESS:
Name |
Designation |
Stake. |
1. B 1. Control unit |
1 |
|
2. B 2. Block of a high voltage |
1 |
|
3. To 3. Cable network |
1 |
|
4. P 4. Grounding wire |
2 |
|
5. P 5. High-voltage wire |
1 |
|
Operational documents |
||
Hands Operation manual |
AV-AV-50/70.00.00.00RE |
1 |