Explosion-proof magnetic contact point burglar detector Ex IO 102 MK (explosion-proof marking 1Ex d IIC T6 Gb / РB Ex d I Mb) buy in Rjazan
ALL.BIZ Russia Russia products Electrical Equipment Electric machines Electric machines, aggregates and their components Electric equipment hardened Explosion-proof magnetic contact point burglar detector Ex IO 102 MK (explosion-proof marking 1Ex d IIC T6 Gb / РB Ex d I Mb)
Buy Explosion-proof magnetic contact point burglar detector Ex IO 102 MK (explosion-proof marking 1Ex d IIC T6 Gb / РB Ex d I Mb)
Explosion-proof magnetic contact point burglar detector Ex IO 102 MK (explosion-proof marking 1Ex d IIC T6 Gb / РB Ex d I Mb)
izveshchatel_ohrannyj_tochechnyj_magnitokontaktnyj
izveshchatel_ohrannyj_tochechnyj_magnitokontaktnyj
izveshchatel_ohrannyj_tochechnyj_magnitokontaktnyj
izveshchatel_ohrannyj_tochechnyj_magnitokontaktnyj

Explosion-proof magnetic contact point burglar detector Ex IO 102 MK (explosion-proof marking 1Ex d IIC T6 Gb / РB Ex d I Mb)

In stock
Price:
4500 RUB
Wholesale:
  • 3900 RUB/pcs  - from 50 pcs
Payment:
  • Cash,
  • Invoice payment,
  • Cash on delivery
  • In detail
Shipping:
  • Customer pickup,
  • Courier,
  • Transport company
  • In detail
Seller
Russia, Rjazan
(View map)
Technical characteristics
  • BrandНПП «МАГНИТО-КОНТАКТ»
  • Country of manufactureRussia
Description

Passport

Certificate of compliance with the requirements of the Technical Regulations of the Customs Union: TR CU 012/2011 "On safety of equipment for operation in explosive atmospheres" No. RU С - RU. BN02.V.00037 / 19 . Valid from 5.02.2019 to 19.12.2023

Certificate of compliance with the requirements of the Technical Regulations of the Customs Union TR CU 012/2011 "On the safety of equipment for operation in explosive atmospheres" No. EAEU RU C - RU. BH02.B.00529 / 20 . Valid from 08/06/2020 to 12/19/2023

Certificate of conformity to the requirements of GOST R 54832 - 2011 "Magnetic contact security point detectors. General technical requirements and test methods" No. ROSS RU.11AK01.N.00433 . Valid from 02/05/2019 to 02/04/2022

Certificate of compliance with the requirements of GOST 30546.1 - 98, GOST 30546.2 - 98, GOST 30546.3 - 98 (seismic resistance performance (9) points on the MSK - 64 scale), category 1 of seismic resistance according to NP - 031 - 01 No. ROSS RU. AM03.N.00197 . Valid from 4.02.2019 to 3.02.2022

Declaration of compliance with the requirements of TR CU 020/2011 "Electromagnetic compatibility of technical equipment" EAEU No. RU D - RU. BN01.V.03003 / 19 . Valid from 12/13/2019 to 12/12/2024

Declaration of Conformity with the requirements of TR EAEU 037/2016 "On the Restriction of the Use of Hazardous Substances in Electrical and Radioelectronic Products" EAEU No. RU D - RU. BN01.V.03007 / 19 . Valid from 12/13/2019 to 12/12/2024

1. Purpose and conditions of use

Explosion - proof magnetic contact point burglar detectors Ex IO102 MK (hereinafter referred to as sensors), designed to control the position of parts of structures and mechanisms, structural elements of buildings and structures for opening or displacement, made of magnetic (steel and alloys) or non - magnetic materials (wood, plastic, aluminum ) with the subsequent issuance of an alarm notification to the control panel or the terminal object device of the notification transmission system.

In terms of explosion protection, the sensors comply with the requirements of TR CU 012/2011 "On safety of equipment for operation in explosive atmospheres", GOST 31610.0 - 2014 (IEC 60079 - 0: 2011) "Explosive atmospheres. Part 0. Equipment. General requirements ", GOST IEC 60079 - 1 - 2011" Explosive atmospheres. Part 1. Equipment with type of protection "flameproof enclosures" d ".

The sensors consist of two components - a magnetically controlled sensor (reed switch unit) and a setting element (magnet unit). The reed switch unit and the magnet unit of the Ex IO102 MK detector are placed in cylindrical metal housings made of aluminum alloy or stainless steel. The reed switch unit is equipped with a cable gland located at the end of the body.

Reed switch units are produced in two modifications under the conditional numbers 200, 300.

Magnet blocks are produced in two modifications under the symbols M 100, M 200.

Reed switch units are equipped with replaceable cable glands of various designs:


- for open laying of cables with a diameter of 6 - 12 mm (index in the designation K);
- for connecting armored cable with a diameter of 6 - 12 mm (index in the designation B);
- for laying the attached cable in a pipe G1 / 2 (TG - 1/2) or G3 / 4 (TG - 3/4);
- for laying the attached cable in a metal hose (KM15, KM20).

 

The detectors are manufactured in accordance with Table 1.

Table 1

PRODUCT NAME TYPE OF RELEASE APPLIED INPUT TYPE FITTING TYPE BODY EXPLOSION PROTECTION MARKING GOST 31610.0 - 2014
Ex IO102 MK N
Spanish 200
normally open Replaceable cable gland with M25 thread TO
B
TG - 1/2
TG - 3/4
KM15
KM20
Stainless steel 12Х18Н10Т 1Ex d IIC T6 . . . Т5 Gb / РB Ex d I Mb
Ex IO102 MK N
isp. 300
switching
Ex IO102 MK Al
Spanish 200
normally open Aluminum alloy D16T 1Ex d IIC T6 . . . T5 Gb
Ex IO102 MK Al
isp. 300
switching

Scheme of designation of detector versions when ordering:

Ex IO102 MK X use xxx Mxxx fitting type PASHK.425119.114TU
1 2 3 4 five 6
detector type body material (N - stainless steel or Al - aluminum alloy) version of the executive unit according to the type of applied reed switch master unit version type of fitting in the removable cable gland:
К - for cable gland Ø6 - 12mm for open installation
В - for armored cable Ø6 - 12mm
TG - 1/2 - for cable laying in a pipe with connecting thread G - 1/2
TG - 3/4 - for laying cables in a pipe with a connecting thread G - 3/4
KM15 - for cable Ø6 - 12mm in metal hose 15mm
KM20 - for cable Ø6 - 12mm in metal hose 20mm
technical conditions

Sample order:

Intruder detector Ех IO102 MK N isp.200 М100 В PASHK 425119.114TU


Security detector in a stainless steel housing, normally open contact, modification of the M100 magnet, cable gland with a fitting for armored cable.

 

Intruder detector Ex IO102 MK Al isp.300 M200 K PASHK 425119.114TU


Security detector in an aluminum alloy casing, changeover contact, magnet modification M200, cable gland Ø6 - 12mm for open installation.

 

The detectors are designed for operation at temperatures from minus 60 ° С to plus 95 ° С, type of climatic modification is UHL1, placement category 1 according to GOST 15150 - 69. The degree of protection of the enclosure is IP66 / IP68 in accordance with GOST 14254 - 2015. In terms of the method of protecting a person from electric shock, the detector complies with class "III" according to GOST IEC 60335 - 1.

Application conditions:

The sensors are classified as explosion - proof electrical equipment of groups I and II in accordance with GOST 31610.0 - 2014 (IEC60079 - 0: 2011) and are intended for use in hazardous areas in accordance with the established explosion protection marking, the requirements of TR CU 012/2011, GOST IEC 60079 - 14: 2011 " Explosive atmospheres. Part 14. ", GOST 31438.2 - 2011 (EN 1127 - 2: 2002)" Explosive atmospheres. Explosion protection and explosion prevention. Part 2. Basic concept and methodology (for underground workings) "other regulatory documents governing the use of electrical equipment in explosive environments, including in underground workings of mines, mines and their surface structures, hazardous for firedamp and (or) combustible dust.

Possible explosive areas of application, categories of explosive mixtures of gases and vapors with air in accordance with GOST IEC60079 - 10 - 1 - 2011, GOST R IEC 60079 - 20 - 1: 2011 and other regulatory documents governing the use of electrical equipment in hazardous areas.

Maintenance of the detectors must be carried out in accordance with the requirements of GOST IEC 60079 - 17: 2011.

2. Specifications

2.1. Constructive design - 2 - block

2.2. The states of the output contacts of the detectors, depending on the distances between their executive and master units on magnetic conductive bases, are given in Tables 1.1 and 1.2 for various modifications of the detectors.

Table 1.1

Conditional number of the magnet modification Distance between the executive and master units, mm, at which the output contacts of the Ex IO102 MK detectors isp. 200 :
closed under the influence of the magnetic field of the driver unit (normal state of the detectors) open (generation of an alarm notification)
M 100 55 and less 75 and more
M 200 35 or less 55 and more

Table 1.2

Conditional number of the magnet modification Distance between the executive and master units, mm, at which the output contacts of the Ex IO102 MK detectors isp. 300 :
switched under the influence of the magnetic field of the driver unit (normal state of the detectors) not switched (generation of alarm notification)
M 100 50 or less 65 and more
M 200 30 or less 50 and more

2.3. The maximum tolerance for the alignment of the sensor and magnet mount is 10 mm.

2.4. Overall dimensions, mm: reed switch block - 97x58x37, magnet block - 100x58x37

2.5. Weight (no more), kg: reed switch unit - 0.65 Magnet unit - 0.48

2.6. The detectors are designed for operation at temperatures from minus 60 ° C to plus 70 ° C (for T6), up to plus 95 ° C (for T5) at a relative humidity of up to 93% at a temperature of plus 40 ° C.

2.7. Atmospheric pressure, kPa: from 84 to 106.7

2.8. Average service life not less than 8 years

2.9. The detector does not contain precious metals (clause 1.2 of GOST 2.608 - 78).

Specifications

PARAMETER VALUE
Maximum switching voltage, V
with marking 1Ex d IIC T6 . . . T5 Gb
with marking 1Ex d IIC T6 . . . Т5 Gb / РB Ex d I Mb

60
27
Maximum switched current, A 0.25
Maximum switched power, W ten
Resistance of closed contacts upon delivery, no more, Ohm 0.16
Resistance of open contacts, not less, kOhm 200
Cross - section of connected wires, mm 2 from 0.35 to 1.5
Sheath protection degree according to GOST 14254 - 2015 IP66 / IP68 in accordance with GOST 14254 - 2015

3. Scope of delivery

Execution unit assembled with cable gland according to the order - 1 piece


Master block - 1 piece
Passport - 1 piece

 

4. Design and principle of operation

4.1. The overall and installation dimensions of the Executive unit Ex IO102 MK are shown in Fig. 1.

4.2. The design and provision of explosion protection of the Ex IO102 MK executive unit are shown in Fig. 2.

4.3. The overall and mounting dimensions of the Ex IO102 MK master block are shown in Fig. 3.

4.4. The design and options of cable glands for burglar detectors Ex IO102 MK are shown in Fig. 4.

4.5. Извещатели выпускаются с нормально разомкнутым и с переключающим контактом. Нормально разомкнутый контакт в дежурном режиме (в поле действия магнита) замкнут и размыкается в режиме «Тревога» (рис.5, а). Переключающий контакт имеет нормально замкнутый и нормально разомкнутый контакты. В дежурном режиме (в поле действия магнита) нормально разомкнутый контакт замкнут, а нормально замкнутый разомкнут, в режиме «Тревога» контакт переключается в противоположное состояние (рис.5, б).

5. Обеспечение взрывозащищённости

Взрывозащита вида взрывонепроницаемая оболочка «d» обеспечивается следующими средствами:

5.1. Электрические элементы датчиков заключены во взрывонепроницаемую оболочку, выдерживающую давление взрыва и исключающую передачу горения в окружающую взрывоопасную среду.

5.2. Explosion resistance and explosion - proofness of the enclosure meet the requirements for electrical equipment of groups I and II in accordance with GOST IEC 60079 - 1 - 2013. The casing is tested for explosion resistance during manufacture in accordance with the requirements of GOST IEC 60079 - 1 - 2011. The parameters of the flameproof joints of the sensor enclosure comply with the requirements of GOST IEC 60079 - 1 - 2011 for electrical equipment of groups I and II. The cable gland provides a permanent and strong cable seal in accordance with the requirements of GOST IEC 60079 - 1 - 2011.

5.3. The design of the sensors is made taking into account the general requirements of GOST 31610.0 - 2014 (IEC 60079 - 0: 2011) for electrical equipment located in hazardous areas. Seals and joints of the body structure elements provide the degree of protection in accordance with GOST 142542015 (IEC 60529: 2013) "Degrees of protection provided by enclosures (IP Code)", given in table 1.

5.4. The mechanical strength of the sensor sheath meets the requirements of GOST 31610.0 - 2014 (IEC 60079 - 0: 2011) for electrical equipment of groups I and II with a high degree of risk of mechanical damage.

6. Ensuring explosion protection during installation

6.1. The operating conditions and installation of the detector must comply with the conditions set forth in the section "Design and principles of operation" of the PUE (6th edition, Ch. 7.3), current PTB and PTE, including chapter ESh - 13 "Electrical installations of explosive industries" and other documents in force in the industry where the detector will be used.

6.2. Connect the cable to the detector in strict accordance with the current "Instructions for the installation of electrical equipment for power and lighting networks in explosive zones" VSN332 - 74 and this passport. The wiring diagram must correspond to Fig. 5.

6.3. Before connecting the detector to the AL, it is necessary to inspect it externally and pay attention to the integrity of the enclosure and the presence of:


6.3.1. Sealing means (cable glands, insert)
6.3.2. Explosion protection markings

 

6.4. No cavities, mechanical damage and corrosion are allowed on the explosion - proof surfaces of assemblies and parts to be disassembled.

6.5. Carefully seal the cable in the socket of the grommet with a tightening torque of the cable gland of at least 40 Nm.

7. Notes on installation and operation

7.1. When placing and operating security detectors, it is necessary to follow the requirements of RD 78.145 - 93 “Systems and complexes of security, fire and security and fire alarms. Rules for production and acceptance of works. "

7.2. К несущей поверхности исполнительный блок и задающий блок крепятся шурупами или винтами через отверстия в основании. Извещатели могут крепиться к вертикальным или горизонтальным рабочим поверхностям, но в положении встречного направления стрелок, нанесенных на корпуса блоков. Габаритные и установочные размеры извещателей приведены на рис.1, рис.3

7.3. Для монтажа необходимо выкрутить кабельный ввод и извлечь: шайбу поз.8, кольцо уплотнительное поз.4, втулку поз.3, герконовый узел поз.6 (рис.2). Произвести разделку кабеля под клеммные зажимы.

7.4. Надеть на кабель извлеченные (п.7.3) детали в обратном порядке.

7.5. Подключить провода к клеммным зажимам платы в соответствии с электрической схемой рис.5. Оголенные участки не должны выступать из клеммного зажима.

7.6 Assemble the detector in the following order (Fig. 2) and in accordance with one of the options for the cable gland used (Fig. 4):


- insert the washer (pos. 3) the sealing ring (pos. 2) into the body
- insert the sensor board together with the connected cable pos. 5 into the body, insert the pressure ring pos. 4 without skewing
- screw the input housing pos. 7 into the detector housing
- insert the cable gland pos. 8 into the bushing housing
- insert the washer pos. 9 into the body (to install the armored cable insert the cone pos. 15)
- insert the fitting, pos. 10, into the body (for an open gasket, the pressure sleeve, pos. 11
- to enter the cable in the pipe, screw the lock nut, pos. 15, onto the fitting pos. 10
- to install the cable in the metal hose and armored cable insert the washer pos. 12
- tighten the nut, pos. 13 (to enter the cable in the pipe, tighten the lock nut, pos. 15)
- Tighten the cable gland until the cable is sealed; the cable must not twist and slip in the cable gland
When installing with an armored cable (Fig. 4 A), cut the armor and evenly distribute between the cone, pos. 16, and the fitting, pos. 10.
When installing the cable in a metal hose (Fig. 4 B), screw the metal hose completely onto the fitting, pos. 10.
When installing the cable in the pipe (Fig. 4B), screw the pipe of the corresponding thread, pos. 18, until it stops on the fitting, pos. 10.

 

DO NOT SKEW RINGS, BUSHINGS, WASHERS AND BOARDS WHEN INSTALLING INTO THE DETECTOR CASE! TO ENSURE RELIABLE EARTHING BETWEEN THE HOUSING AND THE BOARD, A CONTACT RING IS MANDATORY!

7.7. The detector is a non - repairable product.

7.8. When inspecting in accordance with the timing of equipment inspections, it is necessary to check the fastening of the executive and master units, their relative position, the integrity of the cable, the reliability of the cable seal.

8. Marking

The detector body is marked:


- registered trademark of the manufacturer
- designation of the type of electrical equipment
- serial number according to the manufacturer's numbering system
- the name or mark of the certification body and the number of the certificate
- special Ex marking and conditions of use
- degree of protection provided by the enclosure IP66 / IP68
- special sign of explosion safety
- sign of product circulation on the market of the Customs Union

 

9. Warranty obligations

9.1. The manufacturer guarantees the compliance of the detectors with the requirements of the PASHK.425119.114TU technical specifications provided that the consumer observes the rules of storage, transportation and operation.

9.2. The guaranteed shelf life, subject to the requirements for storage conditions, is 4 years from the date of manufacture of the detector.

9.3. The warranty period for the detector is 3 years from the date of commissioning, but no more than 4 years from the date of manufacture.

Attachment 1

(1 - Sensor housing; 2 - Welded platform; 3 - Pressing ring; 4 - O - ring; 5 - Input housing; 6 - Sensitive element; 7 - External clamp for grounding; 8 - Washer) Fig. 3. Overall and mounting dimensions of the driving unit Ex IO102 MK Fig.4a. Design and options of cable glands for burglar detectors Ex IO102 MK. Open cable routing (1 - Sensor housing; 2 - O - ring; 3 - Washer; 4 - Pressing ring; 5 - Sensor board; 6 - Terminal clamp; 7 - Input housing; 8 - Cable seal; 9 - Washer; 11 - Press bushing; 13 - Nut; 14 - Cable) Fig.4b. Design and options of cable glands for burglar detectors Ex IO102 MK. Installing the cable in the metal hose (1 - Sensor housing; 2 - O - ring; 3 - Washer; 4 - Pressing ring; 5 - Sensor board; 6 - Terminal clamp; 7 - Input housing; 8 - Cable seal; 9 - Washer; 10 - Fitting; 12 - Washer; 13 - Nut; 14 - Cable; 17 - Metal hose) Fig. 4c. Design and options of cable glands for burglar detectors Ex IO102 MK. Laying the cable in the pipe (1 - Sensor housing; 2 - O - ring; 3 - Washer; 4 - Pressing ring; 5 - Sensor board; 6 - Terminal clamp; 7 - Input housing; 8 - Cable seal; 9 - Washer; 10 - Fitting; 14 - Cable; 15 - Locknut; 18 - Pipe) Fig.4d. Design and options of cable glands for burglar detectors Ex IO102 MK. Installation of armored cable (1 - Sensor housing; 2 - O - ring; 3 - Washer; 4 - Pressing ring; 5 - Sensor board; 6 - Terminal clamp; 7 - Input housing; 8 - Contact seal; 10 - Fitting; 12 - Washer ; 13 - Nut; 14 - Cable; 16 - Cone; 19 - Armor) Fig. 5 Electrical diagram of the Ex IO102 MK detectors
Contact the seller
Explosion-proof magnetic contact point burglar detector Ex IO 102 MK (explosion-proof marking 1Ex d IIC T6 Gb / РB Ex d I Mb)