Currency RUB
Fire shutter ZO buy in Kropotkin
Buy Fire shutter ZO
Fire shutter ZO
zatvor_ognepregrazhdayushchij_zo
zatvor_ognepregrazhdayushchij_zo

Fire shutter ZO

Products from producer
In stock
Reconfirm the price with seller
Payment:
  • Cash,
  • Invoice payment,
  • Cash on delivery
  • In detail
Shipping:
Seller
Russia, Kropotkin
(View map)
Technical characteristics
  • BrandЭлеватормельмаш
  • Country of manufactureRussia
Description

Fire shutter ZO is designed for automatic shutdown of technological openings in the walls of seed cleaning complexes and workshops for primary processing of grain in the event of a fire in one of its compartments.

The valve meets the requirements of climatic modification U, placement category 3 in accordance with GOST 15150.

Specifications

The main parameters and dimensions of the fire barrier are shown in the table:

No. Parameter name Unit Rev A type
ZO - 600 * 600 ZO - 600 * 1105 ZO - 750 * 875 ZO - 750 * 1205 ZO - 900 * 1025 ZO - 900 * 1230 ZO - 1100 * 1225
1 Working section size, no more
- width mm 600 600 750 750 900 900 1100
- height mm 600 1105 875 1205 1025 1230 1225
2 Fire resistance limit, not less h 1,2
3 Response time, no more sec 2.5
4 Overall dimensions (without rope), no more
- length mm 1450 1450 1450 1450 1450 1450 1450
- width mm 850 850 1000 1000 1150 1150 1350
- height mm 1300 1300 1300 1500 1300 1500 1520
five The gap between the flange and the damper, no more mm ten
6 Weight, no more kg 230 315 315 360 370 415 460

Product structure and delivery set

  • fire block
  • set of accessories
  • the passport

It is allowed to complete a batch with one passport. A batch should be considered the number of locks obtained from one document, but not more than 10 pieces.

The principle of operation of the fire - stop shutter

The shutter consists of two flanges 1 and 31, two shutters 5 and 29. Shutters 5 and 29 are located between the working and idle branches of the conveyor belt. Gear 3 is mounted on the damper axis 5, which meshes with gear 4. Gear 4 is rigidly connected to the lever 6. Lever 28 is fixed on the damper axis 29. Weights 11 and 23 are suspended on levers 6 and 28. Kinematic connection between the dampers 5 and 29 is carried out using two rods 2 and 30, the end of which is fixed closer to the periphery of the flaps. Levers 6 and 28 with weights 11 and 23 suspended from them are held in a vertical position by levers 9 and 25. Levers 9 and 25 contact with levers 6 and 28 through stops 10 and 24. The pivot axes of levers 9 and 25 are located on brackets 7 and 27 . Ropes 12 and 22 with thermal locks 13 and 21 are attached to the levers 9 and 25,

Switches 8 and 26 are installed on brackets 7 and 27, the rollers of which are pressed by levers 6 and 28. The ropes 12 and 22 include manual starting devices 32 and 33. Flanges 1 and 31 are mounted to the fire wall with studs 17.

The principle of operation of the gates is to break the ropes 12 and 22 due to the operation of the thermal lock 13 and 21 under the influence of an increase in temperature in the event of a fire or due to the operation of manual starting devices 32 and 33.

Contact the seller