Currency RUB
KSO-386 Prefabricated chambers for unilateral maintenance of PC "Electromechanical Plant" LLC buy in Stavropol
Buy KSO-386 Prefabricated chambers for unilateral maintenance of PC "Electromechanical Plant" LLC
KSO-386 Prefabricated chambers for unilateral maintenance of PC "Electromechanical Plant" LLC

KSO-386 Prefabricated chambers for unilateral maintenance of PC "Electromechanical Plant" LLC

Products from producer
In stock
Reconfirm the price with seller
Payment:
  • Invoice payment,
  • Cash,
  • Cash on delivery
  • In detail
Shipping:
Seller
Russia, Stavropol
(View map)
+7(8 
Display phones
Less than 1 year old on Allbiz
Technical characteristics
  • BrandООО ПК «Электромеханический завод»
  • Country of manufactureRussia
Description

SYMBOL STRUCTURE

KSO386 - XXXXXXU3

CSR
Single - sided service chamber
3
Modification
86
Year of design development
XX
Primary connection diagram number (according to tables 1 and 2)
XX
Designation of the rated operating current of the main circuit
at Un = 6 kV
1 - 31.5 A;
2 - 50 A;
3 - 80 A;
4 - 100 A;
5 - 160 A;
6 - 630 A
at Un = 10 kV
1 - 31.5 A;
2 - 40 A;
3 - 63 A;
4 - 80 A;
5 - 100 A;
6 - 630 A;
X
The presence of an alarm about blown fuses (0 - absent, 1 - present)
U3
Climatic modification and placement category according to GOST 15150 - 69

Bus bridge

ShMH - X - U3

CMM
Bus bridge
X
P - with disconnectors, without a letter - there are no disconnectors
X
Distance between KSO chambers (1 - 2 m; 2 - 2.5 m; 3 - 3.5 m)
U3
Climatic modification and placement category according to GOST 15150 - 69

TERMS OF USE

The nominal values of climatic factors are in accordance with GOST 15150 - 69.


Height above sea level - no more than 2000 m.
The group of operating conditions in terms of the impact of mechanical factors of the external environment - M1 in accordance with GOST 17516.1 - 90.
Safety requirements - in accordance with GOST 12.2.007.4 - 75.
Fire safety requirements - in accordance with GOST 12.1.004 - 91.

 

TECHNICAL DATA

Rated voltage, kV 6; 10
The highest operating voltage, kV 7,2,12
Rated breaking current of chambers with load break switches, A 630
Limiting through current of chambers with load break switches; kA 51
Thermal withstand current for 1 s of chambers with load break switches, kA twenty
Rated voltage of auxiliary circuits, V:
alternating operating current
100; 127; 220
direct operating current 100; 110; 220
voltage transformer circuits 100
auxiliary transformer circuits 220; 380
The degree of protection provided by the shell is in accordance with GOST 14254 - 96 IP 20
Service life, years fifteen
Contact the seller
KSO-386 Prefabricated chambers for unilateral maintenance of PC "Electromechanical Plant" LLC
KSO-386 Prefabricated chambers for unilateral maintenance of PC "Electromechanical Plant" LLC
Shipping method
Payment method
Compare0
ClearSelected items: 0