Currency RUB
Magnetic hermetic position sensor explosion-proof DPM-1Ex (DPMGR-2) (explosion protection marking 0Ex ia IIC T6 Ga X / PO Ex ia I Ma X) buy in Rjazan
ALL.BIZ Russia Russia products Electrical Equipment Electric machines Electric machines, aggregates and their components GI mining electrical equipment Magnetic hermetic position sensor explosion-proof DPM-1Ex (DPMGR-2) (explosion protection marking 0Ex ia IIC T6 Ga X / PO Ex ia I Ma X)
Buy Magnetic hermetic position sensor explosion-proof DPM-1Ex (DPMGR-2) (explosion protection marking 0Ex ia IIC T6 Ga X / PO Ex ia I Ma X)
Magnetic hermetic position sensor explosion-proof DPM-1Ex (DPMGR-2) (explosion protection marking 0Ex ia IIC T6 Ga X / PO Ex ia I Ma X)
datchik_polozheniya_magnitogerkonovyj

Magnetic hermetic position sensor explosion-proof DPM-1Ex (DPMGR-2) (explosion protection marking 0Ex ia IIC T6 Ga X / PO Ex ia I Ma X)

In stock
Price:
1500 RUB
Wholesale:
  • 1300 RUB/pcs  - from 2 pcs
Payment:
  • Cash,
  • Invoice payment,
  • Cash on delivery
  • In detail
Shipping:
  • Customer pickup,
  • Courier,
  • Transport company
  • In detail
Seller
Russia, Rjazan
(View map)
Products of other enterprises
Technical characteristics
  • BrandНПП «МАГНИТО-КОНТАКТ»
  • Country of manufactureRussia
Description

You can have a DPM - 1Ex (DPMGR - 2) sensor from us at a low price. The DPM - 1Ex (DPMGR - 2) sensor is manufactured in an explosion - proof design.

1. General information

Explosion - proof magnetic hermetic position sensors DPM - 1Ex are designed to control the position of moving individual structures and mechanisms made of magnetic and non - magnetic conductive materials during various technological processes in explosive zones. Structurally, position sensors consist of two components: a magnetically controlled sensor (reed switch unit) and a setting element (magnet unit). The sensors are marked with explosion protection 0Ex ia IIC T6 Ga X / PO Ex ia I Ma X in accordance with GOST 31610.0 - 2014 (IEC60079 - 0: 2011).


The sensors can be used in underground workings of mines, mines and their surface structures, hazardous with firedamp, as well as in other explosive zones in accordance with the established explosion protection marking.

 

The sensors are designed for operation at ambient temperatures from minus 50 to plus 50C and at relative air humidity up to 93% at 40C. In terms of the method of protecting a person from electric shock, the position sensor corresponds to class "III" in accordance with GOST IEC 60335 - 1. Sheath protection degree - IP68 in accordance with GOST 14254 - 2015. The “X” symbol following the explosion protection marking of the position transmitters means that the sensors are manufactured with a permanently connected cable. An "X" indicates the need for a suitable connection of the free end of the cable.

2. Basic parameters and characteristics

2.1. Constructive design - 2 - block.

2.2. DPM - 1Ex sensors are manufactured in accordance with Table 1.

Table 1

PRODUCT NAME TYPE OF RELEASE APPLIED TERMINAL LENGTH, M
WIRE TYPE
BODY
DPM - 1Ex version 00 Normally open 1 * × PVA 2 × 0.75 (double insulation) Plastic
DPM - 1Ex version 02 Switching 1 * × PVA 3 × 0.75 (double insulation)
DPM - 1Ex version 04 Normally open 1 * × PVA 2 × 0.75 (metal hose RZN - material stainless steel)
DPM - 1Ex version 05 Switching 1 * × PVA 3 × 0.75 (metal hose RZN - stainless steel material)
* It is possible to manufacture sensors with a different length and type of output as agreed with the customer

2.3. The sensor contacts are guaranteed to close when the distance between the sensor and the magnet is 25 mm and are kept closed at a distance of up to 40 mm, and are guaranteed to be open at a distance of 90 mm.

2.4 Overall dimensions, mm: reed switch unit 140x20x35; block of magnets 140x24x22

2.5. Weight (no more), kg: reed switch unit 0.30; block of magnets 0.21

2.6. Sensor lead length: 1 m without cutting

2.7. The degree of protection of the enclosure is IP68 according to GOST 14254 - 2015 (IEC60529: 2013).

Terms of Use:

Operating temperature: from minus 50 ° С to plus 50 ° С at relative air humidity up to 93% at 40 ° С.

Atmospheric pressure, kPa: from 84 to 106.7

The electrical parameters of the sensors, depending on the operating conditions and design, are presented in Table 2.

table 2

DESIGN OF THE PRODUCT OPERATING CONDITIONS OF THE DETECTOR
ELECTRICAL SWITCHING PARAMETERS IN THE COMPOSITION OF INTRINSICALLY SAFE CIRCUITS (0EX IA IIC T6 GA X / PO EX IA I MA X)
MAXIMUM INPUT PARAMETERS VALUE MAXIMUM INPUT INTRINSICALLY SAFE PARAMETERS VALUE
DPM - 1Ex version 00,
DPM - 1Ex version 04
- voltage, V
- current, A
- Power, W
250
2
thirty
- voltage Ui, V
- current Ii, mA
- Pi power, W
- internal inductance Li, μH
- internal capacitance Ci, pF
25
200
1,2
ten
50
DPM - 1Ex version 02,
DPM - 1Ex version 05
- voltage, V
- current, A
- Power, W
100
1
thirty
- voltage Ui, V
- current Ii, mA
- Pi power, W
- internal inductance Li, μH
- internal capacitance Ci, pF
25
200
1,2
ten
50

3. Operation and Explosion Proof

3.1. When the magnet unit approaches the reed switch unit, the reed switch contacts switch, at the moment when the field strength created by the permanent magnet becomes equal to the reed switch actuation field strength.

3.2. The explosion protection of position transmitters is ensured by the following means:

3.2.1. The position sensors do not contain electrical components capable of storing energy hazardous to ignite Category I and IIC gases . .

3.2.2. Electric clearances, creepage distances and dielectric strength of insulation meet the requirements of GOST 31610.0 - 2014 (IEC60079 - 0: 2011).

3.2.3. The construction of position sensors is made taking into account the general requirements of GOST 31610.0 - 2014 (IEC60079 - 0: 2011) for electrical equipment located in hazardous areas. Seals and joints of the body structure elements ensure the degree of protection not lower than IP68 in accordance with GOST 14254 - 2015 (IEC60529: 2013).

3.2.4. The electrostatic intrinsic safety of the position transmitter housing is ensured by the choice of materials of construction.

3.2.5. The maximum heating temperature of the surface of the housing of the position sensors does not exceed the permissible values for the temperature class T6 in accordance with GOST 31610.0 - 2014 (IEC60079 - 0: 2011).

3.2.6. On the housings of the position sensors there are the necessary warning notices, explosion protection markings, intrinsically safe parameters of electrical circuits and the "X" sign.

3.3. To ensure the intrinsic safety of the circuit, the manufacturer recommends connecting the sensors through an ISSH ATFE.426439.001TU barrier ([Exia] IIC / IIB marking), which meets the requirements of GOST 30852.0 - 2002 (IEC 60079 - 0: 1998). To connect sensors to a loop, the manufacturer recommends using a USB - Ex "SEVER" ATFE.685552.001TU connecting device (marking 0ExiaIICT6) , which meets the requirements of GOST 30852.0 - 2002 (IEC 60079 - 0: 1998).

1 - red (brown, white),


2 - blue (green, yellow),
3 - white (blue) * It is possible to manufacture sensors with a different length and type of output as agreed with the customer

 

4. Terms of use

4.1. Position sensors belong to explosion - proof electrical equipment of groups I and II in accordance with GOST 31610.0 - 2014 (IEC60079 - 0: 2011) and are intended for use in hazardous areas in accordance with the established explosion protection marking, requirements of TR CU 012/2011, GOST IEC 60079 - 14: 2011 , other regulatory documents regulating the use of electrical equipment in explosive environments, including in underground workings of mines, mines and their surface structures, hazardous for firedamp.

4.2. Possible explosive areas of application, categories of explosive mixtures of gases and vapors with air in accordance with GOST IEC60079 - 10 - 1 - 2011, GOST R IEC 60079 - 20 - 1: 2011 and other documents.

4.3. Installation, operation and maintenance of position sensors must be carried out in accordance with the requirements of GOST IEC 60079 - 17: 2011.

5. Completeness

The delivery set of sensors includes:

  • reed switch unit - 1 pc.
  • block of magnets - 1 pc.
  • passport - 1 pc.

6. Manufacturer's Warranties

The warranty period for the position sensors is 3 years after commissioning, but not more than 3.5 years from the date of shipment from the manufacturer's plant, provided that the consumer observes the conditions of use, transportation and storage.