Maximum heat point fire detectors IP 114-50 (explosion protection marking 0Ex ia IIС Т6 ... Т3 Ga X) buy in Rjazan
Buy Maximum heat point fire detectors IP 114-50 (explosion protection marking 0Ex ia IIС Т6 ... Т3 Ga X)
Maximum heat point fire detectors IP 114-50 (explosion protection marking 0Ex ia IIС Т6 ... Т3 Ga X)
izveshchateli_pozharnye_teplovye_tochechnye

Maximum heat point fire detectors IP 114-50 (explosion protection marking 0Ex ia IIС Т6 ... Т3 Ga X)

In stock
Price:
150 RUB
Wholesale:
  • 140 RUB/pcs  - from 200 pcs
Payment:
  • Cash,
  • Invoice payment,
  • Cash on delivery
  • In detail
Shipping:
  • Customer pickup,
  • Courier,
  • Transport company
  • In detail
Seller
Russia, Rjazan
(View map)
+7(4 
Display phones
Less than 1 year old on Allbiz
Technical characteristics
  • BrandНПП «МАГНИТО-КОНТАКТ»
  • Country of manufactureRussia
Description

Passport

Certificate of compliance with the requirements of GOST R 53325 - 2012 No. RU C - RU. PB65.V.00025 / 19 . Valid from 17.09.2019 to 16.09.2022

Declaration of Conformity with the requirements of TR EAEU 037/2016 "On the Restriction of the Use of Hazardous Substances in Electrical and Electronic Products" EAEU No. RU D - RU. BN01.B.03008 / 19 . Valid from 12/13/2019 to 12/12/2024

Certificate of compliance with the requirements of the Technical Regulations TR CU 012/2011 "On the safety of equipment for operation in explosive atmospheres" No. EAEU RU С - RU. BH02.B.00464 / 20 . Valid from 10.06.2020 to 9.06.2025

Purpose of the product

Maximum heat point fire detectors IP114 - 50 of classes A1, A2, A3, B, C, D, E, F, G are intended for round - the - clock operation in order to detect fire, accompanied by an increase in temperature in closed rooms of various buildings and structures.

The detector belongs to special explosion - proof electrical equipment. Application area of IP114 - 50 - explosive zones of premises and outdoor installations in accordance with explosion protection marking 0ExiaIIС Т6 . . . T3 GaX; GOST IEC60079 - 14 - 2013, chapter 7.3 of the PUE and other regulatory documents governing the use of electrical equipment located in the hazardous area and connected by intrinsically safe external circuits with electrical devices installed outside the hazardous area.

IP114 - 50 detectors of classes A1, A2, A3, B, C, D, E, F, G give information about a fire to the fire or burglar - fire alarm loop of receiving and control devices (hereinafter PPK) by closing or opening the contacts of the thermosensitive element of the detector . . .

Main technical characteristics

The detectors comply with the requirements of the technical regulations of the Customs Union TR CU 012/2011, which establishes on the unified customs territory of the Customs Union uniform requirements for equipment for operation in explosive atmospheres, GOST 31610.0 - 2014 (IEC60079 - 0: 2011), GOST 31610. 11 - 2014 (IEC60079 - 11: 2011) and are marked with explosion protection 0Ex ia IIC T6 . . . Т3 Ga Х according to GOST 31610.0 - 2014 (IEC60079 - 0: 2011), the requirements of GOST R 53325 - 2012, NPB 76 - 98, NPB 85 - 2000. The "X" sign following the explosion protection marking of the detectors means that the temperature class of the detectors is determined depending on the ambient temperature (table 1).

Main technical characteristics

Explosion protection marking 0 Ex ia IIC T6 . . . T3 Ga X
Class of an electrical product according to the method of protecting a person from electric shock in accordance with GOST 12.2.007.0 - 75 III
Maximum intrinsically safe input parameters:
- voltage Ui, V
- current Ii, mA
- Pi power, W
- internal inductance Li, μH
- internal capacitance Ci, pF

thirty
200
1.5
ten
0.6
The degree of protection of detectors IP 114 - 50, provided by the shell in accordance with GOST 14254 - 2015 IP20
Climatic modification according to GOST 15150 UHL4
Transient electrical resistance of closed contacts of the detector no more than 2 Ohm
Weight of detectors IP 114 - 50 no more than 25 g
The maximum switching power of the detector is no more than 1.5 W in the range of switching voltage from 9 to 30 V.
Switching current range of the detector up to 0.5 A
Average service life of detectors at least 10 years
The detector does not contain precious metals (clause 1.2 of GOST 2.608 - 78).

Table 1

Detector class Medium temperature, ° С Response temperature, ° С Temperature class according to GOST 31610.0 - 2014
conditionally normal maximum normal minimal maximum
A1 25 50 54 65 T6
A2 25 50 54 70
A3 35 60 64 76
B 40 65 69 85
C 55 80 84 100
D 70 95 99 115 T5
E 85 110 114 130 T4
F 100 125 129 145
G 115 140 144 160 T3

Figure: a - normally closed contacts (on the detector housing ●)


Figure: b - normally - open contacts (on the detector housing ●●)

 

Completeness

  • Thermal fire detector IP114 - 50 - 1 pc.
  • Remote light indicator IVS - 3 * - 1 pc.
  • Thermal fire detector IP114 - 50 Passport - 1 pc. for packaging

* by agreement with the customer, it is allowed to supply the IP114 - 50 detectors without a remote indicator IVS - 3.

Device and principle of operation

Structurally, the detector is made in a plastic housing consisting of a base and a removable cover. A temperature - sensitive element is installed inside the housing, connected to the terminal block, which also serves to connect the detector to the loop.

The connection diagram for IP114 - 50 and the control panel is shown in Fig. 1.

There are two holes at the base of the detector for mounting on site. Figure 2 shows the overall and mounting dimensions of the detector.

Heat point fire detector maximum IP 114-50 Figure: 1. Scheme of switching on the IP 114 - 50 detector with NC and NO contacts

There are two holes in the base of the heat fire detector for mounting on site. In fig. 2 shows the overall and mounting dimensions of the detector.

Explosion-proof maximum heat point fire detectors IP 103-55 Figure: 2. Overall and mounting dimensions of the detector

Placement and installation

Placement and installation at the controlled facility must be carried out in accordance with the requirements of NPB 88 - 2001 “Fire extinguishing and alarm installations. Norms and design rules "and RD 78.145 - 93" Systems and complexes of security fire and security - fire alarm systems. Rules for production and acceptance of works. "

Heat fire detectors are installed in the upper part of the room and are included in the fire alarm loop. The number of heat fire detectors included in the fire alarm loop is determined by the type of control panel. It is not allowed to place and operate heat fire detectors closer than 1 meter from sources of constant and variable magnetic fields (loudspeakers, transformers, electric motors). The area monitored by one point heat fire detector, as well as the maximum distance between the detectors or the detector and the wall, must be determined according to the table, but not exceeding the values specified in the technical specifications and passports for the detectors.

HEIGHT OF THE PROTECTED AREA, M AVERAGE AREA CONTROLLED BY ONE DETECTOR, SQ. M MAXIMUM DISTANCE, M
BETWEEN DETECTORS FROM DETECTOR TO WALL
Up to 3.5 Up to 25 5.0 2.5
St. 3.5 to 6.0 Up to 20 4.5 2.0
St. 6.0 to 9.0 Up to 15 4.0 2.0

manufacturer's warranty

The manufacturer guarantees the compliance of the heat fire detector with the requirements of the PASHK.425212.135 TU technical conditions, subject to the conditions of transportation, storage, installation and operation.

Mean time between failures not less than 60,000 hours.

The warranty period is 3 years from the date of commissioning, but not more than 3.5 years from the date of shipment of the fire heat detector by the manufacturer, provided that the consumer observes the conditions of transportation, storage and operation, as well as installation requirements. Heat fire detectors, which have been found to have failures during the warranty period, are replaced by a serviceable manufacturer.

Contact the seller
Maximum heat point fire detectors IP 114-50 (explosion protection marking 0Ex ia IIС Т6 ... Т3 Ga X)
Maximum heat point fire detectors IP 114-50 (explosion protection marking 0Ex ia IIС Т6 ... Т3 Ga X)
for
by the goods
Your message must contain at least 20 symbols. The message must not be more than 2000 symbols.
Obligatory field is not filled
The field is wrongly filled
The field is wrongly filled
Shipping method
Payment method
Compare0
ClearSelected items: 0