Range analyzer portable Agilent Technologies N9342C

N9342C portable analyzer of a range Agilent Technologies Range of frequencies is from 100 kHz to 7 GHz The average level of own noise (DANL) - 163/-145dbm (with/without preamplifier) Task manager for automatic testing Analysis of hindrances and spectral monitoring The built-in watching generator Spectral monitoring with function of reproduction of the spectrogram and record Support of the USB measuring instrument of power of Agilent Analysis of modulation ChMn/AMN and ChM/AM The highest accuracy in a class of manual analyzers 4 hours of continuous work from the accumulator The innovative scheduler of tasks for automation of tests The built-in GPS receiver from the built-in GPS antenna Russian-speaking interface

Parameters

Values

Frequency parameters

Range of frequencies (open entrance)

from 100 kHz to 7 GHz (adjusted to 9 kHz)

Error of the internal generator of the basic frequency of 10 MHz

Aging

±1 x 10-6 in a year

Temperature instability

±1 x 10-6

Error of counting of frequency by means of a marker

Permission of a marker

(a review strip) / (number of points of development - 1)

Error

± (frequency of a marker x error of basic frequency
+1% x strip of the review + 20% x bandwidth
+ resolution of a marker is +1 Hz)

Error of basic frequency

speed of aging x time from the moment of the last control + temperature instability

Marker frequency counter

Permission

1 Hz

Error

± (frequency of a marker x error of basic frequency + permission of a marker)
Strip review transmission/strip ≥ 0,02; the marker has to be established more than 25 dB above the displayed level of own noise; value of shift of frequency is equal to 0 Hz

Review strip

N9342C

0 Hz (a zero strip), from 100 kHz to 7 GHz

Permission

1 Hz

Error

± (0,22% x a strip of the review + a review strip / (number of points of development - 1)), number.

One-band phase noise (from 20 °C to 30 °C, the center. frequency is 500 MHz)

detuning from bearing 30 kHz

<-86 dbn/Hz;-89 dbn/Hz (type. value)

detuning from bearing 100 kHz

<-97 dbn/Hz;-101 dbn/Hz (type. value)

detuning from bearing 1 MHz

<-115 dbn/Hz;-119 dbn/Hz (type. value)

Bandwidth (-3 dB)

Installation range

from 10 Hz to 3 MHz, in sequence 1:3:10

Error

± 5% (number), bandwidth from 10 Hz to 1 MHz

±10%, bandwidth = 3 MHz

Coefficient of squareness of the filter (selectivity)

<5: 1 (number.), on levels minus 60 dB / minus 3 dB, digital, gaussopodobny

Video filter strip) (-3 dB)

Installation range

from 1 Hz to 3 MHz, in sequence 1:3:10

Error

±10% (number.), at a strip from 1 Hz to 1 MHz

Amplitude parameters

Limits of measurement of level of a signal (preamplifier off)

from 100 kHz to 2 MHz
from 2 MHz to 7 GHz

from the average level of sobstvo. noise to +10 dBm
from the average level of sobstvo. noise to +20 dBm

Limits of weakening of an entrance attenuator

from 0 to 50 dB

Maximum safe level entrance signalasredny continuous power (installation vkh. attenuator ≥ 20 dB)

N9342C

+33 dBm, no more than 3 min., from 2 MHz to 7 GHz

Tension of a direct current

± 50 V max.

Average level of own noise

(SKZ the detector, averaging of schedules> 40, entrance easing 0 dB, an entrance impedance of 50 Ohms, bandwidth of 1 kHz, the noise given to a strip of 1 Hz, from 20 to 30 °C)

the preamplifier is switched off (basic level ≤-50 dBm)

from 100 kHz do1 MHz of-108 dBm;-127 dBm (type. value)
from 1 to 10 MHz-128 dBm;-146 dBm (type. value)
from 10 to 500 MHz-142 dBm;-146 dBm (type. value)
from 500 MHz to 2,5 GHz-141 dBm;-145 dBm (type. value)
from 2,5 to 4 GHz-140 dBm;-144 dBm (type. value)
from 4 to 6 GHz-138 dBm;-142 dBm (type. value)
from 6 to 7 GHz-136 dBm;-140 dBm (type. value)

the preamplifier is included (basic level ≤-70 dBm)

from 100 kHz do1 MHz of-131 dBm;-150 dBm (type. value)
from 1 to 10 MHz-148 dBm;-163 dBm (type. value)
from 10 to 500 MHz-161 dBm;-164 dBm (type. value)
from 500 MHz to 2,5 GHz-159 dBm;-162 dBm (type. value)
from 2,5 to 4 GHz-158 dBm;-161 dBm (type. value)
from 4 to 6 GHz-155 dBm;-158 dBm (type. value)
from 6 to 7 GHz-150 dBm;-154 dBm (type. value)

Screen scale limits

Logarithmic scale

from 10 dB to 100 dB, 10 divisions are displayed,
1,2,5,10 dB / division

Linear scale

from 0 to 100%, are displayed 10 divisions

Scale units

dBm, dBmV, dbmkv, W, In, dBmV (EMF mode), dbmkv (EMF mode), In (EMF mode)

Number of points of development (schedule)

461

Permission of counting of level on a marker

Logarithmic scale

0,01 dB

Linear scale

≤ 1% of signal level (number.)

Detectors

normal, peak, instant value, negative peak, averaging (logarithm. capacities, SKZ, tension)

Number of schedules

4

Functions of schedules

deleting/record, accumulation of maxima, accumulation of minima, averaging

Error of measurement of level (except mismatch cases on an entrance) (from 20 to 30 °C, the peak detector, a preamplifier is switched off, the level of an entrance signal from-50 to 0 dBm, 95% a percentile, time of development are established for achievement of accuracy of measurements (Swp Time Rule = Accuracy). If time of development is determined for achievement of speed of measurements (Swp Time Rule = to Speed), the additional error ± 0,3 dB is added).

N9342C

±1,5 dB

Basic level

Installation limits

from - 100 to +30 dBm with a step of 1 dB

Logarithmic scale

0,01 dB

Linear scale

As well as for the ravine. scales (from 2,236 mkv to 7,07 B)

Error

0 dB

RF In entrance KSVN (at a control frequency)

from 10 MHz to 3 GHz
from 3 to 7 GHz

<1,5: 1 (number.), easing 10 dB or 20 dB
<2,0: 1 (number.), easing 10 dB or 20 dB

Products of distortions and combinational components

Harmonious distortions of the second order (signal level on the mixer minus 30 dBm, entrance easing 0 dB, a preamplifier off, from 20 to 30 °C)

from 50 MHz to 3 GHz
from 3 to 7 GHz

<-65 dbn
<-70 dbn

Intermodulation distortions of the third order (TOI) (two tones on minus of 20 dBm on an entrance are carried on 100 kHz, entrance easing 0 dB, a preamplifier off, basic level ≥-30 dB, from 20 to 30 °C)

from 50 to 300 MHz
from 300 MHz to 7 GHz

+7 dBm
+10 dBm

Own residual responses (the loaded entrance, osl. 0 dB, preamplifier off)

from 100 kHz to 7 GHz

<-90 dBm;-98 dBm (type. value)

Development

Development time

Limits

from 2 ms till 1000 with (a review strip ≥ 100 Hz)
from 600 nanoseconds to 200 with (a review strip = 0 Hz)

Development mode

continuous, single

Development time mode

for achievement of accuracy of measurements (Accuracy),
for achievement of speed of measurements (Speed)

Start source

automatic machine., video path signal, external, VCh package

Difference of a signal of start

positive or negative (for choice)

Start delay

from ±12 ms to ±12 with (number.), review strip = 0 Hz

Connectors of input-output of the forward panel

VCh entrance (RF input)

Connector and impedance

Ohm type N, 50 (number.)

Entrance of a signal of the basic frequency of 10 MHz / external start (10 MHz reference/External trigger input)

Frequency vkh. basic signal

10 MHz

Amplitude vkh. basic signal

from 0 to +10 dBm

Start level

there corresponds TTL (5 V) (number.)

Connector

BNC (socket), 50 Ohms (number.)

Food of a sampler (Probe power)

Tension/current

+15 V post. current, ±7%, from 0 to 150 ma (number.)
- 12,6 post. current, ±10%, from 0 to 150 ma (number.)

USB ports (USB 2.0 Full Speed are compatible)

Connector host port

USB Type-A (socket)

Device connector

USB Type-mini AB (socket)

LAN

RJ-45, 10 Base-T

General characteristics

Display

Permission

640 x 480 pixels

Size and type

6,5 inches (170 mm), color ZhK display

Languages

Screen graphic interface of the user

English, French, German, the Spanish simplified and traditional Chinese, Japanese, Italian, Korean, Russian, Portuguese

Requirements to food and calibration

Entrance tension of the adapter

from 100 to 240 V of alternating current, from 50 to 60 Hz, automatic choice of limits

Output tension of the adapter

15 V of a direct current, 5,3 A, 80 W, max.

Consumption

15 W (N9342C), 16 W (N9343C/4C), type. value

Time of operation of the battery (after a total charge)

3,5 hours (the watching generator off, a preamplifier off)

Battery charge time

3 hours

Battery service life

from 300 to 500 cycles of a charge

Time ustan. operating mode

30 minutes

Frequency of calibration

1 year

Conditions of environment and mass-dimensional sizes

Working range of temperatures

from-10 to +50 °C (battery: from 0 to +50 °C)

Range of temperatures of storage

from-40 to +70 °C (battery: from-20 to 50 °C)

Relative humidity

<95%

Weight

3,2 kg (weight unpacked); 3,6 kg (with the battery)

Overall dimensions

318 x 207 x 69 mm (width x height x depth)

Shipping method
Contact the seller
Range analyzer portable Agilent Technologies N9342C
Range analyzer portable Agilent Technologies N9342C
for
by the goods
Your message must contain at least 20 symbols. The message must not be more than 2000 symbols.
Obligatory field is not filled
The field is wrongly filled
The field is wrongly filled
Compare0
ClearSelected items: 0