Technical characteristics
  • BrandМегаизол
  • Country of manufactureRussia
Description
Description the polypropylene cloth duplicated by the metallized polypropylene film
Appointment Vapor barrier:
  • protection of a heater and building constructions against penetration of vapors of water from within the room.

Waterproofing:

  • protection of wooden elements of a design and garret overlapping against atmospheric moisture in places of leaky laying of a roof.

Thermal insulation:

  • reflection of a thermal stream from heating system.
Scope Vapor barrier:
  • the warmed cattle roof;
  • the warmed walls;
  • the warmed socle and garret overlappings;
  • when laying a parquet and laminate.

Waterproofing:

  • not warmed cattle roof.

Thermal insulation:

  • "heat-insulated floor" systems; the reflecting screen behind a radiator.
Functionality Vapor barrier:
  • interferes with formation of condensate during the cold period of year and to moistening of a heater (MOISTENING of the HEATER FOR 2,5% LEADS TO LOSS of ITS HEAT-INSULATING PROPERTIES FOR 50-55%);
  • interferes with fungal infection and corrosion of elements of a design;
  • reduces losses of heat due to creation of the additional isolating screen;
  • reflection of heat and economy of costs of the electric power.

Waterproofing:

  • protects from hit in a moisture design from external environment;
  • protects from wind;
  • prevents losses of heat during the cold period;
  • protects from a garret overheat during the summer period.

Thermal insulation:

  • reduces losses of heat on an external wall,
  • increases efficiency of heating devices for 30% and more!;
  • promotes uniform distribution of thermal energy indoors.
Installation Vapor barrier:

Is established from the inside of a heater in designs of the warmed roof and walls. Keeps within a dense prileganiye to a heater the metallized surface in the building.

Waterproofing:

Keeps within on an obreshetka or a flooring from boards the reflecting surface to a roofing covering.

Thermal insulation:

Fastens near a heating element the reflecting surface towards the heated room.

Instruction for Megaizol AL'S installation


Examples of use Megaizol AL


The warmed cattle roof

"Megaizol" is used by AL as subroofing vapor barrier in the warmed roofs with any type of heaters.

Is established from the inside of a heater, the metallized surface in the building, for the purpose of reflection of heat and economy of costs of heating.

For providing conditions of infrared reflection it is necessary to observe a gap between a hydro-vapor barrier otrazhayushcheypoverkhnost "Megaizol of AL" and internal finishing.

Material cloths also stick together by means of a connecting tape "Megaizolsl".

Walls with external warming

"Megaizol AL" as vapor barrier neobkhodimdlya protection of a design of walls against the vapors arising indoors and reflections of a thermal stream in the room for reduction of losses of heat.

Keeps within from the inside of a heater, the metallized surface in the building. For providing conditions of infrared reflection, it is necessary to observe a gap between the reflecting surface of the material "Megaizol AL" and internal finishing.

Panels and places of an adjunction of material to protecting (walls, overlappings) and getting (pipes, antennas) to designs are glued by the tape "Megaizol SL".

Not warmed inclined roof

"Megaizol" is applied by AL as protection of internal roofing designs against subroofing condensate and an overheat of a garret during the summer period.

Material is established by the reflecting surface to a roofing covering with a small gap for providing conditions of infrared reflection.

Cloths are pressurized by means of the connecting tape "Megaizol SL". For prevention of damage of insulating films, in a design of a roof it is necessary to use roofing a sealant.

Garret (socle) overlappings

It is applied as vapor barrier in the warmed interfloor, and also garret (socle) overlappings to protection of a heater of all types against humidity.

Keeps within between sexual logs the metallized surface in the room for the purpose of reflection of heat and economy of costs of heating. It is necessary to observe a gap of 4-5 cm between the reflecting surface of material and material of internal finishing.

In the systems "heat-insulated floors"

"Megaizol" is used by AL as the screen reflecting a thermal stream under heating system.

Keeps within on overlapping, the reflecting surface to the heating element.

Instruction for installation Megaizol AL

Technical characteristics

Explosive loading, prod./poper., N / 5см 205/149
Vapor permeability gr. / (sq.m * 24 h) 0,12
Water resistance, mm.vod. column., not less 1000
Roll sizes 1,5m. * 46,67m. = 70 sq.m.
Shipping method
Payment method
Contact the seller
The reflecting hydro-vapor barrier Megaizol ® AL
The reflecting hydro-vapor barrier Megaizol ® AL
for
by the goods
Your message must contain at least 20 symbols. The message must not be more than 2000 symbols.
Obligatory field is not filled
The field is wrongly filled
The field is wrongly filled
Compare0
ClearSelected items: 0