Currency RUB
The thermal insulation reflecting gidro-paro-Megaizol ® ML 1000 mm.vod.st. buy in St petersburg
Buy The thermal insulation reflecting gidro-paro-Megaizol ® ML 1000 mm.vod.st.
The thermal insulation reflecting gidro-paro-Megaizol ® ML 1000 mm.vod.st.
otrazhayushhaya_gidro_paro_teploizolyacziya_megaizol_ml_1000_mmvodst

The thermal insulation reflecting gidro-paro-Megaizol ® ML 1000 mm.vod.st.

Products from producer
In stock
Price:
1 RUB
For example: +7(50)123-45-67
Payment:
  • Cash,
  • Non-cash,
  • Visa/Mastercard,
  • Cash on delivery
  • In detail
Shipping:
Russia, St petersburg
(View map)
+7(8 
Display phones
3
3 years on Allbiz
Technical characteristics
  • BrandМегаизол
  • Country of manufactureRussia
Description
The thermal insulation reflecting gidro-paro-Megaizol ® ML
Description the made foam not sewed polyethylene laminated by the metallized polypropylene film
Scope Vapor barrier:
  • the warmed cattle roof;
  • the warmed walls;
  • interfloor overlappings;
  • when laying a parquet and laminate.

Waterproofing:

  • not warmed cattle roof.

Thermal insulation:

  • the warmed walls, roof, interfloor overlappings;
  • "heat-insulated floor" systems;
  • the reflecting screen behind a radiator.

Sound insulation:

  • interfloor overlappings;
  • walls; ventilating box and air ducts
Appointment Vapor barrier:

protection of a heater and building constructions against penetration of vapors of water from within the room.

Waterproofing:

protection of wooden elements of a design and garret overlapping against atmospheric moisture in places of leaky laying of a roof.

Thermal insulation:

reflection of a thermal stream from heating system; increase of resistance to a heat transfer without essential increase in thickness

Sound insulation:

reduction of extent of penetration of foreign sounds

Functionality Vapor barrier:
  • interferes with formation of condensate during the cold period of year and to moistening of a heater (MOISTENING of the HEATER FOR 2,5% LEADS TO LOSS of ITS HEAT-INSULATING PROPERTIES FOR 50-55%);
  • interferes with fungal infection and corrosion of elements of a design;
  • reduces losses of heat due to creation of the additional isolating screen;
  • increases resistance to a heat transfer without essential increase in thickness of a design (at the expense of cellular structure of the made foam polyethylene);
  • reflection of heat and economy of costs of the electric power.

Waterproofing:

  • protects from hit in a moisture design from external environment;
  • protects from wind; prevents losses of heat during the cold period;
  • protects from a garret overheat during the summer period.
  • increases resistance to a heat transfer without essential increase in thickness of a design (at the expense of cellular structure of the made foam polyethylene).

Thermal insulation:

  • increases resistance to a heat transfer without essential increase in thickness of a design (at the expense of cellular structure of the made foam polyethylene);
  • the directed reflection of heat in the room to 80%; reduces losses of heat on an external wall, increases efficiency of heating devices for 30% and more!

Sound insulation:

  • reduces the level of noise and vibration
Installation Vapor barrier:

Is established from the inside of a heater in designs of the warmed roof and walls. Keeps within a dense prileganiye to a heater the metallized surface in the building.

Waterproofing:

Keeps within on an obreshetka or a flooring from boards the reflecting surface to a roofing covering.

Thermal insulation:

Fastens near a heating element the reflecting surface towards the heated room.

Examples of use Megaizol ® ML

In the warmed cattle roof:

Use Megaizol ML at installation of a roof allows to increase significantly resistance of a heat transfer of a roofing design without increase in its thickness. Also material carries out functions of a noise isolation and vapor barrier that is necessary in roofs with coverings from a metal tile, a professional flooring, galvanized iron and roofing copper. Is established between the main heater and the internal finishing metallized by the party in the room. At installation it is necessary to provide an air gap of 3-4 cm between the reflecting surface of material and internal finishing. Cloths of material are mounted end-to-end and stick together by means of the connecting tape "Megaizolsl" or the metallized adhesive tape of "Megaizolsk".

Walls with external warming:

Use "Megaizol ML" in a design of walls increases their resistance to a heat transfer without essential increase in thickness. Also material carries out functions of a noise isolation and vapor barrier. "Megaizolml" is established between the main heater and the internal finishing metallized by the party in the room. At installation it is necessary to provide an air gap of 3-4 cm between the reflecting surface of material and internal finishing. Cloths of material are mounted end-to-end. Panels and places of an adjunction of material to protecting (walls, overlappings) and getting (pipes, antennas) to designs are glued by a tape "Megaizolsl" or the metallized adhesive tape of "Megaizolsk".

Not warmed inclined roof

In a design of not warmed roof "Megaizol ML" is applied as hydro-vapor barrier to protection of wooden elements of a design and garret overlapping against atmospheric moisture in places of leaky laying of a roof, and also from subroofing condensate and an overheat of a garret during the summer period. "Megaizol ML" keeps within the metallized surface to the main roofing covering with an obligatory gap of 3-4 cm for providing conditions of infrared reflection. Cloths of material are mounted end-to-end. Joints are glued by the connecting tape "Megaizolsl" or the metallized adhesive tape of "Megaizolsk".

In designs of interfloor overlappings

In designs of interfloor overlappings Isolation "Megaizol ML" in a design of overlappings increases their resistance to a heat transfer without essential increase in thickness of a design. Besides material carries out functions of vapor barrier and a noise isolation.

Keeps within over a heater the reflecting surface in the heated room. Cloths are mounted end-to-end, joints of cloths are surely pressurized by means of the connecting tape "Megaizolsl" or the metallized adhesive tape of "Megaizolsk".

It is necessary to observe a gap of 3-4 cm between the reflecting surface of material and material of internal finishing.

In the systems "heat-insulated floors"

At thermal insulation of floors by means of "Megaizol ML" thermal streams, being reflected from a folgirovanny layer, do not get to the bearing designs under a floor that allows to avoid formation of condensate.

"Megaizol ML" is reliable protection against household and structural noise.

Keeps within on the basis the metallized surface in the heated room, heating elements of "heat-insulated floor" from above are put and the cement coupler keeps within.

As the thermal screen behind a radiator

"Megaizol ML" as the screen reflecting a thermal stream from heating system
  • reduces losses of heat on an external wall,
  • increases efficiency of heating devices for 30% and more!
  • Promotes uniform distribution of thermal energy indoors.
"Megaizol ML" is established near a heating element with a gap of 4-5 cm by the reflecting surface towards the heated room

In designs of ventilating systems, air ducts

Isolation of ventilating boxes by means of "Megaizol ML" will allow to avoid excess heatlosses and will create additional sound insulation, will reduce the level of noise and vibration of ventilating systems.

It is necessary to wrap up "Megaizol ML" around a ventkorob the reflecting metallized surface outside and to record by means of glue or the stapler, to glue all seams an aluminum adhesive tape "Megaizol SK".

For isolation of pipes, capacities, a metalwork

Isolation of pipes and capacities will create additional conditions of energy saving.
At a difference of temperatures of pipes, a metalwork and environment there is a condensate loss.
"Megaizol ML" completely will relieve application of the reflecting thermal insulation of condensate and, as a result, of corrosion and destruction, and will also create additional sound insulation, will reduce the level of noise and vibration.

It is necessary to wrap up "Megaizol ML" around a pipe the metallized surface outside and to record by means of glue, to glue all seams an aluminum adhesive tape "Megaizol SK".

Instruction for Megaizol ML'S installation

Technical characteristics of material

Explosive loading, prod./poper., N / 5см 130/108
Water resistance, mm.vod.st., not less 1000
Roll size 1 m * 30 m = 30 sq.m.

1 m * 10 m = 10 sq.m.

Shipping method
Payment method
Contact the seller
The thermal insulation reflecting gidro-paro-Megaizol ® ML 1000 mm.vod.st.
The thermal insulation reflecting gidro-paro-Megaizol ® ML 1000 mm.vod.st.
for
by the goods
Your message must contain at least 20 symbols. The message must not be more than 2000 symbols.
Obligatory field is not filled
The field is wrongly filled
The field is wrongly filled
Compare0
ClearSelected items: 0